ADSS is an all-dielectric self-supporting loose tube cable designed for aerial installation on power utility poles and communication corridors. Tubes are jelly filled and laid up around a non-metallic central strength member, bound with polyester yarn, wrapped with water blocking tape, reinforced with aramid yarn and finished with a PE outer sheath. No metallic components are r


ADSS is an all-dielectric self-supporting loose tube cable designed for aerial installation on power utility poles and communication corridors. Tubes are jelly filled and laid up around a non-metallic central strength member, bound with polyester yarn, wrapped with water blocking tape, reinforced with aramid yarn and finished with a PE outer sheath. No metallic components are required, so the cable can be installed o
ADSS is an all-dielectric self-supporting loose tube cable designed for aerial installation on power utility poles and communication corridors. Tubes are jelly filled and laid up around a non-metallic central strength member, bound with polyester yarn, wrapped with water blocking tape, reinforced with aramid yarn and finished with a PE outer sheath. No metallic components are required, so the cable can be installed o
Fully dielectric, non-metallic construction with aramid yarn strength for self-supporting aerial spans
Loose tube design available from 6 to 144 fibers with 4 or 12 fibers per tube
Maximum allowable tension 3000 N; short-term crush 1000 N/100 mm
Rated span 120 m with wind speed up to 35 km/h and 0 mm ice thickness
Cable diameter 10.5-16.3 mm; weight 83-202 kg/km depending on fiber count
Tensile and crush tests per IEC 60794-1-2 E1/E3 with no fiber break or sheath damage
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Blue | Orange | Green | Brown | Gray | White | Red | Black | Yellow | Purple | Pink | Aqua |
| SN | Item | Unit | Value | ||||
|---|---|---|---|---|---|---|---|
| 1 | No. of fibers | count | 6/8 / 12 | 24 | 36/48 | 96 | 144 |
| 2 | No. of fibers per tube | count | 4 | 4 | 12 | 12 | 12 |
| 3 | No. of elements | count | 6 | 6 | 6 | 8 | 12 |
| 4 | Thickness of outer sheath | mm | 1.7 | 1.7 | 1.7 | 1.7 | 1.7 |
| 5 | Cable diameter ( ±5% ) | mm | 10.5 | 10.5 | 11.2 | 12.8 | 16.3 |
| 6 | Cable weight ( ±10% ) | kg/km | 83 | 89 | 99 | 133 | 202 |
| 7 | Maximum allowable tension | N | 3000 | ||||
| 8 | Short-term crush | N/100mm | 1000 | ||||
| 9 | Span | m | 120 | ||||
| 10 | Wind speed | Km/h | ≤35 | ||||
| 11 | Ice thickness | mm | 0 |
| Item | Test Method | Acceptance Condition |
|---|---|---|
| Tensile Strength IEC 60794-1- 2- E1 | – Load: Maximum allowable tension – Length of cable: about 50m – Load time : 1min | – Fiber strain ≤0.33% – No fiber break and no sheath damage. |
| Crush Test IEC 60794-1- 2- E3 | – Load: Short-term crush – Load time : 1min | – Loss change ≤0.1 dB@1550nm – No fiber break and no sheath damage. |
| Mode field diameter (1310nm) | 9.2 μm ± 0.4 μm |
|---|---|
| Mode field diameter (1550nm) | 10.4 μm ± 0.8 μm |
| Cut off wavelength of cabled fiber ( l cc ) | ≤1260nm |
| Attenuation at 1310nm | ≤0.36dB/km |
| Attenuation at 1550nm | ≤0.22dB/km |
| Bending loss at 1550nm (100 turns, 30mm radius) | ≤0.05dB |
| Dispersion in the range 1288 to 1339nm | ≤3.5ps/ (nmkm) |
| Dispersion at 1550nm | ≤18ps/ (nmkm) |
| Dispersion slope at zero dispersion wavelength | ≤0.092ps/ (nnm2 km) |
Why choose an all-dielectric cable? With no metal parts, ADSS can be installed on energized power lines without bonding or grounding and is immune toinduced voltage and lightning effects. What span can ADSS support? The standard design covers a 120 m span with wind speeds up to 35 km/h; longer or heavier loading designs can be engineered on request. What fiber counts are offered? Standard configurations range from 6/8/12 to 144 fibers in loose tubes of 4 or 12 fibers each.
Full manufacturer datasheet is available on request from PNA Fiber.
Contact PNA Fiber for OEM/ODM branding, customization, volume pricing and lead time.
Cable configurations vary by model. Refer to the specification tables above for fiber count, single-mode/multimode type and construction details.
Armored and self-supporting variants are designed for aerial routes; duct and buried types are also available. See the model-specific structure table above.
Yes. Custom lengths, jacket printing and packaging can be arranged. Contact us for a quotation.