Provide one-stop FTTH products and solutions since 2008 year

OPGW CABLE
OPGW Cable
OPGW Cable
OPGW Cable
OPGW Cable

Optical Fibre Composite Overhead Ground Wire (Uni-tube)

Optical fibre composite overhead ground wire (OPGW) is an overhead ground wire containing optical fibre. It has multiple functions such as overhead ground wire and optical communication. It is mainly used for communication lines of 110KV, 220KV, 500KV, 750KV and new overhead high-voltage transmission system. It can also be used to replace the existing ground lines of the old overhead high voltage transmission system, add the optical communication line, transmit short time current and provide anti lightning protection. Other structures can be customized on request.
  • Stainless steel tubes filled with hydrophobic gel provide the protection and support of the optical fibres
  • Good tensile performance
  • Small diameter, light weight, low additional load to the tower
  • Appropriate fibre excess length of optical unit easliy to make
Edit Content

Optical Ground Wire (OPGW) – The Ultimate Solution for Utility Communications

Optical Ground Wire, or OPGW, is a cutting-edge technology that integrates both grounding and fiber optic communication capabilities into a single overhead cable. Designed for high-voltage transmission lines ranging from 110kV to 750kV, OPGW offers a versatile and cost-effective solution for modern utility communication needs.

Characteristics
  • Stainless steel tubes filled with hydrophobic gel provide the protection and support of the optical fibres
  • Good tensile performance
  • Small diameter, light weight, low additional load to the tower
  • Appropriate fibre excess length of optical unit easliy to make
Optical Fibre Characteristics
Attenuation Bandwidth Polarization Mode Dispersion
 

@850nm

 

@1300nm

 

@1310nm

 

@1550nm

 

@850nm

 

@1300nm

Individual Fibre Design Link Value (M=20, Q=0.01%)
G652D ≤0.35dB/km ≤0.21dB/km ≤0.20ps/ km ≤0.1ps/ km
G655 ≤0.22dB/km ≤0.20ps/ km ≤0.1ps/ km
50/125μm ≤3.0dB/km ≤1.0dB/km ≥600MHz.km ≥1200MHz.km
62.5/125μm ≤3.5dB/km ≤1.0dB/km ≥200MHz.km ≥600MHz.km
Classification Material Value
 

 

 

Construction

Optical Fibre G652D/G655 etc. 2 – 48
Protection Tube Stainless steel tube 1.5 – 6mm
Stranded Line AS wire/AA wire/Al Rod 1.5 – 6mm
Max. Diameter 18mm
Max. Cross Section 200mm2
 

 

 

 

Characteristic

According to the standards as DL/T 832, IEC60794-4-10, IEEE1138
Max. Tensile Strength (RTS ) (kN) 280
Max. Crush Strength(N/100mm) 2200
Max. Short Current Capacity (40℃-200℃)(kA2s) 100
Min. Bending Radius (Dynamic) 20D
Min. Bending Radius (Static) 15D
Environment Performance Installation (℃) -10 to +50
Transportation and Operation (℃) -40 to +65

Note: D is cable diameter.

Specific Type and Technical Data
No. Technical Data
Product Type Structure Type Max. Fibre Count Section of AS Wire
(mm2)
Diameter

(mm)

Cable Weight
(kg/km)
Rate Tensile Strength

(kN)

20℃DC

Resistance

(Ω/km)

Short Time Current Capacity

(40-200℃ kA2.s)

1 OPGW-24B1.3-40-[51;9] 6/3.0/20AS, Optical Unit 1/3.0 24 ≈40 9.0 ≤304 ≥51 ≤2.10 ≥9
2 OPGW-24B1.3-50-[58;11.5] 6/3.2/20AS, Optical Unit 1/3.2 24 ≈50 9.6 ≤345 ≥58 ≤1.82 ≥11.5
3 OPGW-48B1.3-70-[77;24] 6/3.8/20AS, Optical Unit 1/3.8 48 ≈70 11.4 ≤475 ≥77 ≤1.30 ≥24
4 OPGW-48B1.3-70-[42;38] 6/3.8/40AS, Optical Unit 1/3.8 48 ≈70 11.4 ≤340 ≥42 ≤0.70 ≥38

**Other optical fibre type and count, stranded wire are available om request.

Mechanical and Environmental Test Characteristics
Item Test Method Requirements
 

 

 

Tension

IEC 60794-1-2-E1

Load: according to cable structure

Sample length: no less than 10m, linked length no less than100m

Duration time: 1min

 

40%RTS no additional fibre strain(0.01%), no additional attenuation (0.03dB).

60%RTS        fibre        strain≤0.25%,additional        attenuation≤0.05dB

(No additional attenuation after test).

 

 

Crush

IEC 60794-1-2-E3

Load: according to above table, three points Duration time: 10min

 

Additional attenuation at 1550nm ≤0.05dB/fibre; No damage to the elements

 

 

Water Penetration

IEC 60794-1-2-F5B

Time : 1 hour Sample length: 0.5m Water height: 1m

 

 

No water leakage.

 

 

 

Temperature Cycling

IEC 60794-1-2-F1

Sample length: No less than 500m Temperature range: -40℃ to +65℃

Cycles:   2

Temperature cycling test dwell time: 12h

The change in attenuation coefficient shall be less than 0.1dB/km at 1550nm.
Packaging and Drum
  • Standard Cable Drum
  • Standard reel length: 2/3km/reel, other length is also available
Edit Content
Supporting Cross Section 135.9 mm2
Section of AS Wire 22.64 mm2
Edit Content

Shipping by Air/ Express/ Sea freight. [Please contact us for any question]

Edit Content

Reviews

There are no reviews yet.

Be the first to review “Optical Fibre Composite Overhead Ground Wire (Uni-tube)”

Your email address will not be published. Required fields are marked *

To: Wade OY - Commercial Director

info@pna-tech.com

By requesting a quote, your information will be shared with P&A Electronics Technology Co., Ltd. according to Google's Privacy Policy so that the merchant can follow up on your request.
WordPress Cookie Plugin by Real Cookie Banner
× How can I help you?