ITU-T g.654e ultra-low-loss single-mode fiber for long-haul and high-capacity backbone transmission OEM/ODM supply from PNA Fiber.


ITU-T g.654e ultra-low-loss single-mode fiber for long-haul and high-capacity backbone transmission OEM/ODM supply from PNA Fiber.
ITU-T g.654e ultra-low-loss single-mode fiber for long-haul and high-capacity backbone transmission OEM/ODM supply from PNA Fiber.
ITU-T G.654E ultra-low-loss single-mode fiber for long-haul and high-capacity backbone transmission.
Suitable for C-band (1530-1565nm) and L-band (1565~ 1625nm) 40G/100G/ultra-long-distance transmission.
The large effective area reduces non linear effects in fiber transmission, ensuring good system transmission performance.
Ultra-low attenuation, meeting the transmission requirements of ultra-long distances with high dynamic fatigue parameters.
1550nm and more sensitive 1625nm window has low bending loss.
Excellent protective coating and superior peel ability.
| Characteristic | Condition | Data | Unit | |
| Optical features | ||||
| Attenuation | 1310nm | ≤0.344 | [dB/km] | |
| 1383nm(After hydrogen aging) | ≤0.344 | [dB/km] | ||
| 1550nm | ≤0.204 | [dB/km] | ||
| 1625nm | ≤0.24 | [dB/km] | ||
| Attenuation change relative towavelength | 1285-1330nm,compared to 1310nm | ≤0.05 | [dB/km] | |
| 1525-1575nm,comparedto 1550nm | ≤0.05 | [dB/km] | ||
| Dispersion in the wavelength range | 1285-1340nm | ≤3.5 | [ps/(nm ·km)] | |
| 1550nm | ≤18 | [ps/(nm ·km)] | ||
| 1625nm | ≤22 | [ps/(nm+km)] | ||
| zero dispersion wavelength(λO) | — | 1300~1324 | [nm] | |
| Zero dispersion slope(SO) | — | ≤0.092 | [ps/(nm2-km)] | |
| Polarization Mode Dispersion Coefficient (PMD) | single fiber maximum | — | ≤0.1 | [ps/(km)1/2] |
| Fiber link value (M=20,Q=0.01%) | — | ≤0.06 | [ps/(km)1/2] | |
| Typical value | — | 0.03 | [ps/(km)1/2] | |
| Cable cut-off wavelength(λcc) | — | ≤1260 | [nm] | |
| Modefield diameter(MFD) | 1310nm | 8.8~9.6 | [μm] | |
| 1550nm | 9.8~10.8 | [μm] | ||
| Effective group index of refraction (Neff) | 1310nm | 1.466 | ||
| 1550nm | 1.467 | |||
| Point discontinuity | 1310nm | ≤0.05 | [dB] | |
| 1550nm | ≤0.05 | [dB] | ||
| Claddingdiameter | — | 125.0±0.7 | [μm] |
| Cladding out-of-roundness | ≤1.0 | [%] | |
| Coating diameter | 235~250 | [μm] | |
| Cladding/CoatingConcentricity Error | ≤12.0 | [μm] | |
| Coating out-of-roundness | ≤6.0 | [%] | |
| Core/Clad Concentricity Error | — | ≤0.6 | [μm] |
| Warpage(Radius) | – | ≥4 | [m] |
| Delivery length | up to 50.4 | [km/tray] |
| Temperature Additional Attenuation | -60℃to 85℃ | ≤0.05 | [dB/km] |
| emperature-Humidity Cycling Additional Attenuation | -10℃to 5℃,98%RH | ≤0.05 | [dB/km] |
| Water immersion additional attenuation | 23℃,30 days | ≤0.05 | [dB/km] |
| Thermal additional attenuation | 85℃,85%relative humidity,30 days | ≤0.05 | [dB/km] |
| dry heat aging | 85℃,30 days | ≤0.05 | [dB/km] |
| Screening tension | ≥9.0 | [N] | ||
| — | ≥1.0 | [N] | ||
| ≥100 | [kpsi] | |||
| 30mm 100 turns,radius 30mm | 1625nm | ≤0.05 | [dB] | |
| Macrobending additional loss | 25mm 100 turns,radius25mm | 1310nm and 1550nm | ≤0.05 | [dB] |
| 16mm 1 turn,radius 16mm | 1550nm | ≤0.05 | [dB] | |
| typical average | ≥1.0 | [N] | ||
| Coatingpeel force | peak | 1.3~8.9 | [N] | |
| dynamic fatigue Parameter (nd) | ≥20 | |||
ITU-T g.654e ultra-low-loss single-mode fiber for long-haul and high-capacity backbone transmission The G.654E cut-off wavelength shifted fiber is supplied by PNA Fiber for telecom, FTTH, data center and FPV projects. It is available for OEM/ODM orders with custom lengths, packaging and project-specific documentation. Explore the full PNA optical fiber range .
What is the G.654E cut-off wavelength shifted fiber used for? It is used for iTU-T G.654E ultra-low-loss single-mode fiber for long-haul and high-capacity backbone transmission. Contact PNA Fiber with your link length, core count and installation method for a confirmed specification. Can PNA Fiber supply this fiber with OEM branding and custom specs? Yes. We supply private-label packaging, custom lengths, connectorization options and project documentation for OEM/ODM and tender projects. Which standards does this fiber comply with? The specification section above lists the relevant ITU-T / IEC
Contact PNA Fiber for OEM/ODM branding, customization, volume pricing and lead time.
Full technical details are listed in the specification section above. Contact our team if you need the complete datasheet.
Yes. OEM/ODM branding, custom specifications and packaging options are available on request.
Please contact our sales team via the Request a Quote button with your required model and quantity.
PNA Fiber · FIBER OPTICS · pna-fiber.com