GJFJU-1F is a simplex indoor optical cable built around a single buffered fiber. The 0.9 mm LSZH buffer fiber is wrapped with aramid yarn strength members and finished with a 3.0 mm black TPU jacket. It uses G.657A2 bend-insensitive fiber and is designed for patch cords, equipment interconnects and indoor FTTH wiring.


GJFJU-1F is a simplex indoor optical cable built around a single buffered fiber. The 0.9 mm LSZH buffer fiber is wrapped with aramid yarn strength members and finished with a 3.0 mm black TPU jacket. It uses G.657A2 bend-insensitive fiber and is designed for patch cords, equipment interconnects and indoor FTTH wiring.
GJFJU-1F is a simplex indoor optical cable built around a single buffered fiber. The 0.9 mm LSZH buffer fiber is wrapped with aramid yarn strength members and finished with a 3.0 mm black TPU jacket. It uses G.657A2 bend-insensitive fiber and is designed for patch cords, equipment interconnects and indoor FTTH wiring.
Single-fiber simplex design with 0.9 +/- 0.05 mm LSZH buffer
Aramid yarn strength member with a 3.0 +/- 0.1 mm black TPU outer jacket
G.657A2 bend-insensitive fiber with low macro-bend loss at 1550/1625 nm
Short-term tensile strength 700 N and crush 500 N/100 mm
Cable attenuation ≤0.4 dB/km at 1310 nm and ≤0.3 dB/km at 1550 nm
Flame resistance per IEC 60332-1; operating temperature -20 to +70 C
| No. | 1 |
|---|---|
| Fiber color | Natural |
| No. | 1 |
|---|---|
| Buffer color | Blue |
| Item | Unit | Specification | |
|---|---|---|---|
| G.657A2 | |||
| Mode field diameter | 1310nm | μm | 8.6± 0.4 |
| 1550nm | μm | 9.6± 0.5 | |
| Cladding diameter | μm | 124.3~125.0 | |
| Cladding non – circularity | % | ≤1.0 | |
| Core concentricity error | μm | ≤0.5 | |
| Coating diameter | μm | 245± 5 | |
| Coating / cladding concentricity error | μm | ≤10 | |
| Cable cut- off wavelength | nm | ≤1260 | |
| Attenuation Coefficient | 1310nm | dB / km | ≤0.35 |
| 1550nm | dB / km | ≤0.21 | |
| Macro – bend loss (1 turn ,7.5 mm radius ) | 1550nm | d B | ≤0.5 |
| 1625nm | d B | ≤1.0 |
| Item | Contents | Unit | Value |
|---|---|---|---|
| Fiber cores | Count | / | 1 |
| Bu ffer fiber | Dia meter | μm | 0.9±0.05 |
| Materi al | / | L SZH | |
| Stre ngth member | Materi al | / | Aramid yarns |
| Outer jac ket | Dia meter | μm | 3.0±0.1 |
| Materi al | / | T PU | |
| Color | / | Bl ack | |
| Tensile s trength | Short-term | N | 700 |
| Cru sh | Short-term | N/100mm | 500 |
| Cable att enuation | dB / km | ≤0.4 at 1310nm, ≤0.3 at 1550nm | |
| Cable weight ( Approx . ) | k g / km | 8.0 |
| Item | Test Me thod | Acceptance Condition |
|---|---|---|
| Tensile Strength IEC 60794-1-2-E1 | – Load : Short-term tension – Length of cable : ≥50m – Load time : 30min | – Loss change ≤0.1 dB @1550 nm after test . – No fiber break and no sheath damage . |
| Crush Test IEC 60794-1-2 -E3 | – Load : Short-term crush – Load time : 5min | – Loss change ≤0.1 dB @1550 nm after test . – No fiber break and no sheath damage . |
| I m pact Test IEC 60794-1-2 -E4 | – Points of impact: 3 – Times of per point: 1 – Im pact energy :1 J – Striking surface :300mm | – Loss change ≤0.1 dB @1550 nm after test . – No fiber break and no sheath damage . |
| T o rsion IEC 60794-1-2 -E7 | – Length : 1 m – Twist angle : ±180° – No . of cycle : 10 | – Loss change ≤0.1 dB @1550 nm after test . – No fiber break and no sheath damage . |
| Repeated Bending IEC 60794-1-2 -E6 | – Bending radius: 20 x OD – No. of cycle: 25 – Load : 20 N | – No fiber break and no sheath damage . |
| Temperat ure Cycling IEC 60794-1-2 -F1 | – Temperature : -20 C ~+70 C – Time of ea ch step : 8 h – Number of cycle: 2 | – Loss change ≤0.5 dB @1550 nm . – No fiber break and no sheath damage . |
| Flame resistan ce | – IEC 60332- 1 |
What fiber is inside GJFJU-1F? A single G.657A2 bend-insensitive fiber in a 0.9 mm LSZH buffer, identified by a natural fiber color and blue buffer color. What jacket material is used? A 3.0 mm black thermoplastic polyurethane (TPU) jacket over aramid yarn strength members. Is the cable flame retardant? Yes. Flame resistance is tested to IEC 60332-1.
Full manufacturer datasheet is available on request from PNA Fiber.
Contact PNA Fiber for OEM/ODM branding, customization, volume pricing and lead time.
Cable configurations vary by model. Refer to the specification tables above for fiber count, single-mode/multimode type and construction details.
Armored and self-supporting variants are designed for aerial routes; duct and buried types are also available. See the model-specific structure table above.
Yes. Custom lengths, jacket printing and packaging can be arranged. Contact us for a quotation.
PNA Fiber · FIBER OPTIC CABLE · pna-fiber.com
You must be logged in to post a review.
Reviews
There are no reviews yet.